Book Title: Vaastu Principles English
Author(s): Ankit Mishra
Publisher: Ankit Mishra

Previous | Next

Page 28
________________ N FREE download Music and Vastu Book (PDF) (15 visit www.dwarkadheeshvatu.com Skewed Plots NorthEast Facing Constructions Bore well shall Even for going For ground Compound Wall / Parapet Wall / Railing always be up, door is kept in floor, main NorthEast s ide North West & towards East. the debilitating entrance Compound wall In E South East Septic Side tank side consequent door shall parapet wall should Compound wall / should be in North to staircase this always be at always be shorter and side. Other would not be a parapet exalted wall's thinner in comparison rooms, kitchen, fault. thickness should be place. of all other sides. No toilet etc may be similar 1 to one glass pieces or spikes W placed another. as per are allowed here. convenience. Main Door 1 Staircase should Boring Compound / parapet wall shall be thicker and higher on be minimum three Thickness of South West sides. Glass pieces/spikes may also be placed here. North East wall feet away from Stair must be minimum. North East & Roof top construction / Over head water tank / Thickness of North West walls. North West & Placing of other things There shall not be SouthEast side wall N_ must be same. any basement in Such constructions on roof should best North East facing Thickness of be as shown on place no. 1. While SouthWest wall must be construction. constructing ensure that start from place more then all the walls. 1 and proceed towards place 2 in rectangular shape. ensure at least 3 feet Shaft / Duct / Open Area of space as shown. These may be placed only in the Duplex House / Magazine Floor unshaded area as shown. These N. E The shaded areas are appropriate for shall be away at least 3 feet from multilevel constructions. However the the main walls. Building top roof for the whole construction including that on the shaded area shall be only one without any difference in it's Size of the Rooms levels. Septic Tank Rool w Floor level vis a vis road and drainage Room Rooms towards NorthEast should be always smaller in size in comparison to rooms South West. N10E Room +2 Feet Building The floor level of the construction should be at least two feet above the road and drainage should be from the shaded area only. Location of doors 3 Construction of Slab N z Room/ Kitchen/ Store/ Temple / Toilet etc. Doors should always be at places indicated in the map. Kitchen/ Store Kitchen and store can be anywhere in the construction but shelves shall always be in South West wall as shown and never on North East, South East & North West walls. Prayer Room Slabi w Construction of Toilet N Building The shaded area shown in figure either in the building or in the room or appropriate for purposes of prayer. Toilet Sheet ODIO Toilet may be anywhere in the building however the seat be such that during it's use person should face only North or South and never in East & West. Central Area Shelves / Loft / Almirah Center There shall be no construction of ditches, sumps at this place. Including bore well, septic tank etc. or else whole family will be ruined. Room Shelves / Lofts, almirah, heavy furniture etc can be placed in any room on South West walls and away from the corner as shown.

Loading...

Page Navigation
1 ... 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100